Spectrometer 1
(VIS)
|
OceanOptics* USB4000
|
Detector |
Toshiba TCD1304AP linear CCD array |
Scanning range: |
350nm - 1100 nm |
Number of Pixels |
3648 |
Pixel Size |
8 μm x 200 μm |
Pixel Well Depth |
~100.000 electrons |
Optical Design |
f/4, Symmetrical crossed Czerny-Turner |
Focal length |
42mm input |
Aperture |
standard 50 µm wide slit, other sizes are possible (5, 10, 25, 50, 100, 200) |
Grating |
Grating #3, 350nm - 1000nm, best efficient (>30%) 350nm - 850nm |
Detector Len |
L4, to increases light-collection efficiency |
DET4-350-1000 Filter |
OFLV Variable Longpass Order-sorting Filter, to block second- and third-order light |
Optical Fiber connector |
SMA 905 to 0.22 NA single-strand optical fiber |
Optical resolution |
For 50μm slit ~2.0nm (FWHM), for different slit size 0.3nm - 10nm |
Signal-to-noise ratio |
300:1 |
A/D resolution |
16 bit |
Dark noise |
50 RMS counts |
Acquisition time |
10 milliseconds to 10 seconds |
Corrected linearity |
>99.8% |
|
|
|
Spectrometer 2
(NIR)
|
OceanOptics* NIRQuest 512
|
Detector |
Hamamatsu G9204-512 InGaAs linear array (cooled) |
Scanning range: |
850nm - 1700 nm |
Number of Pixels |
512 |
Pixel Size |
25 µm x 500 µm |
Pixel Well Depth |
~100.000 electrons |
Optical Design |
f/4, Symmetrical crossed Czerny-Turner |
Focal length |
42mm input |
Aperture |
standard 50 µm wide slit, other sizes are possible (10, 25, 50, 100, 200) |
Grating |
Grating NIR3, 150 l/mm, 900-1700 nm |
Filter |
OF1-RG830 longpass NIR filter, to block second- and third-order light |
Optical Fiber connector |
SMA 905 to 0.22 NA single-strand optical fiber |
Optical resolution |
With 50μm slit ~3.6nm (FWHM), with different slit size 2.0nm - 12.3nm |
Signal-to-noise ratio |
15000:1 @ 100msec integration, 13000:1 @ 1000msec |
A/D resolution |
16 bit |
Dark noise |
6 RMS counts @ 100msec integration, 12 RMS counts @ 1000msec |
Acquisition time |
1 milliseconds to 120 seconds |
Corrected linearity |
>99.8% |
|
|
|
|
Light Source
|
Lamp type
|
Tungsten Halogen Light Source
|
Wavelength range
|
360-2000 nm
|
Shutter
|
Manual or software control
|
Output
|
20 watts (tungsten halogen)
|
Color Temperature
|
3000oK
|
Lifetime
|
~2000 hours (tungsten halogen)
|
Time to Stabilize
|
~10min
|
|
|
|
|
General characteristics
|
Sample size
|
8mm - 200mm (irregular shape)
|
Computer requirements
|
PC with Windows XP/Vista and a USB port available
|
Power requirements
|
115VAC/230VAC (0.6A/0.3A)
|
Sort cut circuit
|
Slow Blow Fuse 5A.
|
Dimensions (W x L x H)
|
Standard Size: 440mm x 360mm x 180mm, Other sizes are possible to meet particular needs
|
Weight
|
~16Kgr, depending on the configuration
|
|
|
|
|
|
|