Cuvette Holder 2 waysCuvette Holder that can host 10mm path length rectangular cuvettes (3.5ml volume), for Absorbance/Transmittance measurements. Cuvette holder for cylindical cuvettes with 100mm optical path length (28.2ml volume) is also available. |
|
Cuvette Holder 4 waysCuvette Holder that can accommodate 10mm path length rectangular cuvettes (3.5ml volume) and with 4 optical connections, for Absorbance/Transmittance and also Fluorescense measurements. |
|
Film/Cuvette HolderA special Holder that supports a) Absorbance/Transmittance measurements of samples up to 10mm thick and b) liquid samples in standard rectangular cuvettes with 10mm path length (3.5ml volume). |
|
Film/Cuvette Holder - Integrating SphereA high efficient special Holder that supports a) Absorbance/Transmittance measurements of samples up to 10mm thick and b) liquid samples in standard rectangular cuvettes with 10mm path length (3.5ml volume). |
|
Flow cellVarious types of flow cells are available with different optical path lengh:
|
|
MicroFluidic cellA specially designed Microfluidic cell for the monitoring of Bio-interactions on a standard 25mm x 75mm microscope slide. |
|
Reflection Probe HolderA special Holder, offering manual X-Y-Z positioning of the reflection probe, for measurement the reflectance of solid samples or/and measure the thickness of single or multilayer films. |
|
Integrating Sphere Holder - ReflectanceA Super Structure with X-Y-Z manual movement, for precise positioning of the integrating sphere over the measurement area. |
|
Integrating Sphere Holder - IrradianceA Super Structure with X-Y-Z manual movement, for precise positioning of the integrating sphere over the measurement area for irradiance measurements. |
|
Hot plateFor real time measurements of reflectance and film thickness, under thermal treatment (up to 200oC), e.g. polymer films (glass transition temperature, degradation temperature...), bioreactions* etc. It comes with a computer/manual operated PID temperature controller. It may be combined with an external chiller for cooling. Standrad size is 5" OD, other sizes are available on request. * requires a flow cell. |
|
Liquid vesselFor real time film measurements in liquid environment with or without stabilized temperature, e.g. for resist dissolution, coating resistance etc. It may combined with external chiller for cooling under environment temperature. The standard vessel can accommodate samples of any shape, up to 100mm in diameter. The solution volume is 450cc. |
|
Gas ChamberFor real time films measurements under controlled gas ambient, e.g. for swelling measurement of polymer film, coated resistance etc. It may be combined with hot plate and with external chiller for cooling. |